In December 2009, the Florida legislature unanimously passed the Aldridge-Benge Firefighter Safety Act (Florida Statute 633.027), a law that requires
the identification of commercial, industrial, or multi-unit residential
buildings that contain light-frame construction.
The law is named after two
Efforts to pass this legislation were made a higher priority following the deaths of nine firefighters in
The law requires owners of building that contain light-frame construction
to apply markings to the building exterior. The required marking is an 8" Maltese cross that includes one of the
following:
Structures with light-frame truss roofs shall be marked with the letter
"R."
Structures with light-frame truss floor systems shall be marked with the
letter "F."
Structures with light-frame truss floor and roof systems shall be marked
with the
letters "RF."
Light-frame (or light-weight) construction is a broad definition of newer types of construction that
have become more popular since the 1950s.
The goal of light-frame construction is reduced cost of building materials,
faster build time, and reduced cost to the buyer.
It is important to understand these construction methods in order to understand
what is actually covered (and not covered) by the new law.
|
|
Most light-frame forms of construction are based on the truss.
Trusses take advantage of the strength of the triangle, and trusses have
largely replaced traditional wooden joists/rafters in floor and roof assemblies,
and steel I-beams in commercial buildings.
Trusses also offer the ability to span large areas creating an uninterrupted
floor space free of supporting columns.
Nowadays, trusses (and other lightweight components) are designed by computer programs and built off-site to exacting standards
and dimensions, then delivered to the building site.
Light-frame construction has long been recognized by the fire service for the potential danger of premature collapse.
While light-frame construction meets or exceeds industry standards for
strength and durability, these buildings can become unsafe for interior
firefighting much faster than buildings that use more traditional building components.
Of the five basic types of construction, lightweight components can be found within these three:
Note: Type 1 construction (Fire Resistive) may contain lightweight components
but these are "protected" by a membrane or fire-resistant coating. For this reason Type 1 buildings present a reduced collapse risk when compared to Types
II, III, and V.
|
|
Most commercial buildings (excluding high rises) use Type II construction,
most commonly masonry walls with steel roof assemblies.
|
|
These buildings can be single or multiple story, and are often referred to as "taxpayers" or "brick and
joist" buildings.
Masonry walls with wood floors define this construction type.
Modern Type III uses light-frame wood instead of traditional joists or
tongue and groove planking.
|
|
Buildings where the frame is entirely wood, although the exterior can be wood, stucco, block, or brick veneer.
This not only includes single-family dwellings but apartments, townhouses,
condominiums, and some hotels up to four stories in height.
Repetitive wood trusses are more commonly used instead of the more traditional solid wood.
While a joist or rafter is a solid wood member (2 x 8, 2 x 10, 2 x 12)
with considerable mass, truss elements are smaller in size (usually 2x4)
and have an open web configuration. The wood members are usually connected with metal truss plates (commonly called gusset plates).
There are several truss designs (see chart) and they can be used as floor or roof assemblies.
However, all trusses are not necessarily lightweight. Heavy timber trusses such as the bowstring truss use heavier wood members
although these are far less common in
|
|
|
|
All trusses have top chords, bottom chords, and web members.
When used in floor or flat roof assemblies, trusses also eliminate the
horizontal fire separation previously found when solid wood components
were used.
This permits unchecked fire spread within the truss assembly.
|
|
These are commonly referred to as "bar joists" but the proper
term is "open web steel truss."
These can be built using light gauge to heavy gauge steel, and may often contain simple angle
iron for the top and bottom chords and rebar for the web members.
Steel trusses are very common in
While steel is a very strong building material, fire can weaken steel prematurely
to the point of collapse.
Steel begins losing strength at temperatures lower than actual flame temperatures.
A significant load above the steel framing (such as air handlers or accumulated
rainwater) can further weaken the structure.
This includes a very broad variety of building materials and their use
has increased in the past two decades.
Engineered wood uses wood products and industrial adhesives to make engineered
wood in the shape (and strength) of traditional lumber.
Plywood is a form of engineered wood that has been in common use in the
U.S. Building industry for well over 100 years.
One major concern about engineered wood is the performance of adhesives
under fire conditions. While independent testing of these adhesives confirms their strength, the
fire service remains skeptical.
|
|
In the quest for less expensive wood products, the following engineered
woods have been developed:
OSB and LVL have replaced plywood in many building applications, while
LSL is used to make beams for headers, lintels, and other load-bearing components.
|
|
One type of engineered wood product deserves special attention — the wooden I-joist.
This combines the appearance of a joist with the chord design of a truss
— it contains a top and bottom chord made of 2x3 or 2x4 lumber or engineered
wood, with a web of relatively thin OSB.
Like all engineered wood products, these meet industry standards for strength
but have been identified as the cause of premature collapse in several recent fires nationwide.
Due to the thin web component, burn-through is rapid, thus sacrificing
the bottom chord and precipitating collapse.
|
|
We are all familiar with the strength and mass of the traditional steel
I-beam. Steel is also used in fire-resistive construction (Type I) to reinforce concrete.
However, a lighter form of steel construction has been developed that can
be used in place of the open web steel truss. These are called "C" or "Z" beams depending on their shape (sometimes
called "purlins").
They contain considerably less mass than I-beams and are therefore more
susceptible to weakening when exposed to fire.
Expect these beams to weaken much like an open web steel truss.
|
|
These use a combination of wood and steel. There are many variations.
Most often wood is used for the chords and light gauge steel or tubing
used for the webs.
The photo here shows a truss plate incorporated into the metal web members.
Now that we have a better understanding of light-frame construction, let's
take a closer look at the specifics of the Aldridge-Benge Firefighter Safety Act. The original wording is contained in Florida Statute 633.027, with a subsequent
Florida Administrative Code to provide direction in implementation.
Here are the major components of the Florida Administrative Code:
"The purpose of this rule is to require the placement of an identifying
symbol on structures constructed with a light-frame truss component in
a manner sufficient to warn persons conducting fire control and other emergency
operations of the existence of light-frame truss-type construction in the
structure."
"Light-frame truss-type construction" means a type of construction
whose primary structural elements are formed by a system of repetitive
wood or light gauge steel framing members."
The definition above has created confusion within the fire service, code
enforcement agencies, and the building industry. While the wood truss is clearly identified, other forms of lightweight
construction are not as clearly included despite the intent of the original
law.
|
|
In 2010, Chief Financial Officer and State Fire Marshall Alex Sink issued
a declaratory statement in an effort to clarify the definition of light-frame
construction. This statement specifically excluded lightweight steel construction including the open web steel truss and the
C/Z beam.
It is still unclear if the wooden I-joist meets the requirements of the
law.
In response to this, the Florida Fire Marshals and Inspectors Association
(FFMIA) has proposed additional legislation that clearly defines light-frame construction.
If this legislation is approved, all forms of light-frame construction described in this lesson will be
included in the law.
|
|
You may have already seen these signs appearing on buildings in your response
district.
They are required to be a minimum of 8 inches in diameter, must be located between
4' and 6' from the ground, and located within 24" to the left of the main entrance.
Additionally, if the building is longer than 100' or contains multiple
tenants (such as a strip mall) multiple signs may be required.
This law can be a beneficial tool for firefighters when evaluating a structure
prior to interior attack. However, every firefighter must understand the weaknesses of the law in
its current form. As stated previously not all forms of light-frame weight construction are currently addressed
by the law.
This law also specifically exempts some buildings.
Any multi-unit residential building (apartment complex or condominium)
with three units or less is not required to identify light-frame construction.
Townhouses are also excluded (a townhouse is a connected residential building
that has a two-hour fire separation between units).
And keep in mind that single-family dwellings are the largest user of light-frame
construction and the majority of firefighter fatalities occur in single-family
dwellings.
|
|
To summarize, it appears that the intent of the original legislation has
fallen short. While many buildings will be marked in accordance with the law, it will
take time to fully comply, and further interpretation may be forthcoming as
It is incumbent upon each company officer, incident safety officer, and
chief officer to continue to rely upon pre-planning, training, and experience
to identify buildings that contain light-frame construction, and make every
effort to continuously evaluate the safety of operating within these buildings.
While the presence of a light-frame marking may aid in identifying light-frame
construction, the absence of such a marking does not guarantee that the
building is free of light-frame components.
|
|